Steady-State Meter Bars

We employ a modified version of the ASTM D-5470 standard for measuring thermal conductivity and thermal contact resistance.  The modification enables improve measurement reproducibility and accuracy when combined with high precision thermocouples.  The technique is used to characterize the performance of advanced thermal interface materials.